Emissions and distribution characteristics of heavy metal in 1000MW near-zero emission coal-fired units |
WANG Shu-min1, GU Yong-zheng2, YANG Jian-xing3, JIANG Yi-feng3, YU Xue-hai4, ZHANG Zhi-yuan3, WANG Jia-wei5, WANG Tao5, ZHANG Yong-sheng5 |
1. China Energy Investment Corporation, Beijing 100011, China; 2. China Shenhua Energy Co., Ltd., Guohua Power Branch, Beijing 100025, China; 3. Shenhua Guohua Shouguang Power Generation, Weifang 262714, China; 4. Shenhua Guohua (Beijing) Electric Power Research Institute, Beijing 100018, China; 5. North China Electric Power University, School of Energy, Power and Mechanical Engineering, Beijing 102206, China |
|
|
Abstract The EPA Method 29 was used to sample the 1000 MW unit in Shouguang ultra-supercritical coal-fired power plant, the whole process monitoring of heavy metal pollutants (As, Pb, Se, Cd) at multiple points can be realized. The mass balance of heavy metals in the coal combustion process was established, and the enrichment and distribution characteristics of heavy metals in flue gas in coal-fired power plants were studied. The results showed that the heavy metal content of the flue gas was relatively low, the flue gas emission concentrations of As, Se, Pb and Cd were 1.11μg/m3, 0.59μg/m3, 0.33μg/m3 and 0.01μg/m3 at 100% load, respectively, and the heavy metal content at 45% load was close to that at 100% load. The distribution of various heavy metals in coal-fired units under different loads was presented. Pb, Se, and Cd are all enriched in fly ash, but the proportion of Se and Cd in the bottom slag increased significantly at low load. The removal rates of ESP for As, Pb, Se and Cd all reached more than 97% in the APCDs, and WFGD and WESP can deeply remove heavy metals under different loads.
|
Received: 21 October 2021
|
|
|
|
|
[1] |
能子礼超,孙 劲,杨 红,等.烟气单质汞氧化去除过程络合反应机理 [J]. 中国环境科学, 2019,39(9):3727-3735. Nengzi L C, Sun J, Yang H, et al. Study on the mechanism of complexation reaction in the process of mercury removal from flue gas [J]. China Environmental Science, 2019,39(9):3727-3735.
|
[2] |
郑逸武,段钰锋,汤红健,等.燃煤烟气污染物控制装置协同脱汞特性研究 [J]. 中国环境科学, 2018,38(3):862-870. Zheng Y W, Duan Y F, Tang H J, et al. Characteristics of the existing air pollutant control devices on Hg synergistic removal in a coal-fired power plant [J]. China Environmental Science, 2018,38(3):862-870.
|
[3] |
王云鹤,李海滨,黄海涛,等.重金属在煤气化过程的分布迁移规律及控制 [J]. 中国环境科学, 2002,22(6):556-560. Wang Y H, Li H B, Huang H T, et al. Distribution rule and control of heavy metals during coal gasification [J]. China Environmental Science, 2002,22(6):556-560.
|
[4] |
邓 双,张 凡,刘 宇,等.燃煤电厂铅的迁移转化研究 [J]. 中国环境科学, 2013,33(7):1199-1206. Deng S, Zhang F, Liu Y, et al. Lead emission and speciation of coal-fired power plants in China [J]. China Environmental Science, 2013,33(7):1199-1206.
|
[5] |
Clean air act amendments of 1990 [R]. U.S. Environmental Protection Agency, 1990.
|
[6] |
Air pollutant emission inventory guidebook: technical report9 [R]. European Environment Agency, 2009.
|
[7] |
Tian H Z, Lu L, Hao J M, et al. A review of key hazardous trace elements in Chinese coals: Abundance, occurrence, behavior during coal combustion and their environmental impacts [J]. Energy & Fuels, 2013,27(2):601-614.
|
[8] |
张银晓,卢春颖,张 剑,等.民用燃煤排放细颗粒中金属元素排放特征及单颗粒分析 [J]. 中国环境科学, 2018,38(9):3273-3279. Zhang Y X, Lu C Y, Zhang J, et al. Emission characteristics and individual particle analysis of metals in fine particles emitted from residential coal burning [J]. China Environmental Science, 2018,38(9): 3273-3279.
|
[9] |
电力发展“十三五”规划(2016-2020) [R]. 国家能源局, 2016. 13th five-year plan for electric power development (2016-2020) [R]. National Energy Administration of China, 2016.
|
[10] |
黄亚继,金保升,仲兆平,等.煤燃烧过程中痕量元素的分类研究 [J]. 东南大学学报, 2003,33(2):26-30. Huang Y J, Jin B S, Zhong Z P, et al. Study on groups of trace elements during coal combustion [J]. Journal of Southeast University (Natural Science Edition), 2003,33(2):26-30.
|
[11] |
Klika Z, Bartoňová L, Spears D A. Effect of boiler output on trace element partitioning during coal combustion in two fluidised-bed power stations [J]. Fuel, 2001,80(7):907-917.
|
[12] |
岳 勇,陈 雷,姚 强,等.燃煤锅炉颗粒物粒径分布和痕量元素富集特性实验研究 [J]. 中国电机工程学报, 2005,25(18):74-79. Yue Y, Chen L, Yao Q, et al. Experimental study on charcteristics of particulate matter size distribution and trace elements enrichment in emissions form a pulverized coal-fired bolier [J]. Proceeding of the CSEE, 2005,25(18):74-79.
|
[13] |
Zhang Q, Zheng Y X, Tong D, et al. Drivers of improved PM2.5 air quality in China from 2013 to 2017 [J]. Proceedings of the National Academy of Sciences of the United States of America. 2019,116(49): 24463-24469.
|
[14] |
Wang J, Zhang Y, Liu Z, et al. Coeffect of air pollution control devices on trace element emissions in an ultralow emission coal-fired power plant [J]. Energy & Fuels, 2019,33(1):248-256.
|
[15] |
Zheng C, Wang L, Zhang Y, et al. Partitioning of hazardous trace elements among air pollution control devices in ultra-low-emission coal-fired power plants [J]. Energy & Fuels, 2017,31(6):6334-6344.
|
[16] |
Guo X, Zheng C G, Cheng D. Characterization of arsenic emissions from a coal-fired power plant [J]. Environmental Science, 2006,27(6): 1822-1826.
|
[17] |
Cheng C M, Hack P, Chu P, et al. Partitioning of mercury, arsenic, selenium, boron, and chloride in a full-scale coal combustion process equipped with selective catalytic reduction, electrostatic precipitation, and flue gas desulfurization systems [J]. Energy & Fuels, 2009,23(10): 4805-4816.
|
[18] |
Yokoyama T, Asakura K, Matsuda H, et al. Mercury emissions from a coal-fired power plant in Japan [J]. Science of the Total Environment, 2000,259(1-3):97-103.
|
[19] |
HJ766-2015 固体废物 金属元素的测定 电感耦合等离子体质谱法 [S]. HJ766-2015 determination of metal elements in solid waste by inductively coupled plasma mass spectrometry [S].
|
[20] |
HJ700-2014 水质65种元素的测定 电感耦合等离子体质谱法 [S]. HJ700-2014 determination of 65elements in water quality by inductively coupled plasma mass spectrometry [S].
|
[21] |
HJ657-2013 空气和废气 颗粒物中铅等金属元素的测定电感耦合等离子体质谱法 [S]. HJ657-2013 Determination of lead and other metal elements in air and exhaust particulates by inductively coupled plasma mass spectrometry [S].
|
[22] |
GB/T 14848-2017 地下水质量标准 [S]. GB/T 14848-2017 Groundwater quality standard [S].
|
[23] |
华 伟,孙和泰,祁建民,等.燃煤电厂超低排放机组重金属铅,砷排放特性 [J]. 热力发电, 2019,48(10):65-70. Emission characteristics of Pb and As from an ultra-low emission coal-fired power plant [J]. Thermal Power Generation, 2019,48(10):65-70.
|
[24] |
Zheng C H, Wang L, Zhang Y X, et al. Co-benefit of hazardous trace elements capture in dust removal devices of ultra-low emission coal-fired power plants [J]. Journal of Zhejiang University-Science A, 2018,19(1):68-79.
|
|
|
|