Experimental study on rapid recovery of low temperature biological iron and manganese removal process |
WANG Yu-lin1, LI Dong1, YANG Hang2, ZENG Hui-ping1, ZHANG Jie1,2 |
1. Key Laboratory of Beijing for Water Quality Science and Water Environment Recovery Engineering, Beijing University of Technology, Beijing 100124, China;
2. State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin 150090, China |
|
|
Abstract In order to achieve the rapid recovery of biological iron and manganese removal process in the low-temperature (3~5℃), three kinds of recovery methods, including different filtration methods of the upper and lower flow, changing the the influent iron concentration and adding inorganic carbon, were adopted to study the recovery effect on the damaged biological filter column. The results showed that three recovery methods could effectively shorten the recovery time of biological filter column and the recovery times were 40, 54 and 35d, Compared with the conventional recovery mode of 2# filter column, the recovery times of 1# and 3# filter column were shortened by 26%, 35%. Although the recovery time was longer by the way to change the concentration of iron and manganese, but the manganese removal performance after the recovery of the filter column was more stable. From comprehensive consideration of the recovery effect and economic rationality, It was suggested that the best way to recover damaged filter column was iron and manganese concentration increased from low to high and adding inorganic carbon when the filtration rate to 2~3m/h.
|
Received: 09 May 2017
|
|
|
|
|
[1] |
Pacini V A, María Ingallinella A, Sanguinetti G. Removal of iron and manganese using biological roughing up flow filtration technology[J]. Water Research, 2005,39(18):4463-4475.
|
[2] |
Katsoyiannis I A, Zouboulis A I. Biological treatment of Mn(Ⅱ) and Fe(Ⅱ) containing groundwater:kinetic considerations and product characterization[J]. Water Research, 2004,38(7):1922-1932.
|
[3] |
Burger M S, Krentz C A, Mercer S S, et al. Manganese removal and occurrence of manganese oxidizing bacteria in full-scale biofilters[J]. Journal of Water Supply Research and Technology, 2008,57(5):351-359.
|
[4] |
Štembal T, Marki? M, Briški F, et al. Rapid start-up of biofilters for removal of ammonium, iron and manganese from ground water.[J]. Journal of Water Supply Research and Technology, 2004,53(7):509-518.
|
[5] |
Thapa C R, Suzuki I, Takezaki J, et al. Bacterial Diversity in Biological Filtration Plant for the Removal of Iron and Manganese from Groundwater[J]. Journal of Water and Environment Technology, 2013,11(1):33-47.
|
[6] |
Abu Hasan H, Sheikh Abdullah S R, Tan Kofli N, et al. Effective microbes for simultaneous bio-oxidation of ammonia and manganese in biological aerated filter system[J]. Bioresource Technology, 2012,124(1):355-363.
|
[7] |
张杰,李冬,杨宏,等.生物固锰除锰机理与工程技术[M]. 北京:中国建筑工业出版社, 2005:1-27.
|
[8] |
李冬,张杰,陈立学,等.生物除铁除锰在地下水处理厂的应用[J]. 中国给水排水, 2004,20(12):85-88.
|
[9] |
李冬,曾辉平.高铁锰地下水生物净化技术[M]. 北京:中国建筑工业出版社, 2015.
|
[10] |
Tang Y, Wu W, He Y, et al. Low-temperature domestication of an iron and manganese oxidizing bacteria[J]. Advanced Materials Research, 2012,374-377:826-830.
|
[11] |
D A Ratkowsky, R K Lowry, T A, et al. McMeekin, A. N. Stokes, R. E. Chandler, Model for bacterial culturegrowth rate throughout the entire biokinetic temperaturerange,[J]. Bacteriol, 1983,154:1222-1226.
|
[12] |
Ratkowsky D A, Olley J, T. A, et al. McMeekin, A. Ball, Relationship between temperature and growth rate ofbacterial cultures,[J]. Bacteriol, 1982,149:1-5.
|
[13] |
Cai Y A, Li D, Liang Y, et al. Operational parameters required for the start-up process of a biofilter to remove Fe, Mn, and NH3-N from low-temperature groundwater[J]. Desalination and Water Treatment, 2016,(57):3588-3596.
|
[14] |
李冬.生物除铁除锰理论与工程应用技术研究[D]. 北京:北京工业大学, 2004.
|
[15] |
曾辉平.生物除铁除锰滤池长期运行后除锰能力下降原因的探究[D]. 哈尔滨:哈尔滨工业大学, 2007.
|
[16] |
张杰.生物滤层中Fe2+的作用及对除锰的影响[J]. 中国给水排水, 2001,(9):14-16.
|
[17] |
Atta S Kh, Mojammed S A, Van Cleemput O, et al. Transformations of iron and manganese under controlled Eh, Eh-pH conditions and addition of organic matter r[J]. Soil Technology, 1996,9:223-237.
|
[18] |
曾辉平.含高浓度铁锰及氨氮的地下水生物净化效能与工程应用研究[D]. 哈尔滨:哈尔滨工业大学, 2010.
|
[19] |
Cahyani V R, Murase J, Ishibashi E, et al. Bacterialcommunities in manganese nodules in rice field subsoils:estimation using PCRDGGE and sequencing analyses[J]. Soil Sci. Plant Nutr, 2007,53(5):575-584.
|
[20] |
Carmichael M J, Carmichael S K, Santelli C M, et al. Mn (Ⅱ)-oxidizing bacteria are abundant and environmentally relevant members of ferromanganese deposits in caves of the upper Tennessee River Basin.Geomicrobiol[J]. Geomicrobiology Journal, 2013,30(9):779-800.
|
[21] |
Cai Y A, Li D, Liang Y, et al. Effective start-up biofiltration method for Fe, Mn, and ammonia removal and bacterial community analysis[J]. Bioresource Technology, 2015,176:149-155.
|
[22] |
李冬,路健,等.低温生物除铁除锰工艺快速启动与滤速的探求[J]. 中国环境科学, 2016,36(1):82-86.
|
[23] |
Tekerlekopoulou A G, Pavlou S, Vayenas D V. Removal of ammonium, iron and manganese from potable water in biofiltration units:a review[J]. Journal of Chemical Technology and Biotechnology, 2013,88(5):751-773.
|
[24] |
程庆峰.高铁锰氨氮地下水净化工艺优化及菌群结构研究[D]. 哈尔滨:哈尔滨工业大学, 2014.
|
[25] |
Hoyland V W, Knocke W R, Falkinham J O, et al. Effect of drinking water treatment process parameters on biological removal of manganese from surface water[J]. Water Research, 2014,66:31-39.
|
[26] |
GB/T5750-2006生活饮用水标准检验方法[S].
|
[27] |
蔡言安.含铁锰氨氮地下水生物净化试验研究[D]. 北京:北京工业大学, 2015.
|
[28] |
Huang S Q F M, et al. Fe (Ⅱ) and Mn (Ⅱ) removal from drilled well water:A case study from a biological treatment unit in Harbin[J]. Desalination, 2009,245(1-3):183-193.
|
[29] |
Yang H, Li D, Zhang J, et al. Design of biological filter for iron and manganese removal from water[J]. Journal of Environmental Science & Health Part A Toxic/hazardous Substances & Environmental Engineering, 2006,39(6):1447.
|
|
|
|