Utilizing three step feed A/O process to treate comprehensive wastewater from hair product production cluster area
XIAO Cai-lin1,2, SHEN Jian-hua1, YANG Yang3, LI Rui-hua1
1. State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210046, China;
2. Shenzhen Municipal Design & Research Institute Co. Ltd., Shenzhen 518029, China;
3. Hennan Urban and Rural Planning and Design General Institute Co. Ltd., Zhengzhou 450000, China
A three step feed A/O process was utilized as a secondary biological treatment unit to treat comprehensive wastewater from hair product production cluster area. The removals of chemical oxygen demand (COD), TN, PO43--P and the features of microbial communities were investigated at different inflow distribution and sludge return. With volume distribution ratio of anoxic and oxic zone 1:1, solid residence time (SRT) 20d, hydraulic retention time (HRT) 16h, inflow distribution and sludge return were 60%:25%:15% and 75%, average TN and COD concentrations were 14.85mg/L and less than 40mg/L, respectivekly, in effluents from the three step feed A/O process. At the same time, removal efficiency of PO43--P reached the maximum value of 56.21%. Relative abundances of Proteobacteria and Bacteroidetes, the dominating phyla for treating comprehensive wastewater, were 45.63%~60.13% and 16.65%~30.55%. The increasing relative abundances of Denitratisoma, Thauera, uncultured-f-Saprospiraceae, Sulfuritalea, et al. was the essential embodiment that removal efficiency of TN increased with the increase of inflow distribution in the first step or the decrease of sludge return.
肖才林, 沈建华, 杨洋, 李睿华. 三段A/O工艺处理发制品产业集聚区综合废水[J]. 中国环境科学, 2018, 38(4): 1304-1311.
XIAO Cai-lin, SHEN Jian-hua, YANG Yang, LI Rui-hua. Utilizing three step feed A/O process to treate comprehensive wastewater from hair product production cluster area. CHINA ENVIRONMENTAL SCIENCECE, 2018, 38(4): 1304-1311.
Foess G W, Jarrett P, Williams B G. Economic benefits of chemically assisted primary treatment step feed and anoxic zones[J]. Proceedings of the Water Environment Federation, 2003,1(1):313-323.
Wang Z B, Miao M S, Kong Q, et al. Evaluation of microbial diversity of activated sludge in a municipal wastewater treatment plant of northern China by high-throughput sequencing technology[J]. Desalination and Water Treatment, 2016,3:1-6.
Wang W, Wang S, Peng Y, et al. Enhanced Biological Nutrients Removal in Modified Step-feed Anaerobic/Anoxic/Oxic Process[J]. Chinese Journal of Chemical Engineering, 2009,17(5):840-848.
Vaiopoulou E, Melidis P, Aivasidis A. An activated sludge treatment plant for integrated removal of carbon, nitrogen and phosphorus[J]. Desalination, 2007,211:192-199.
[18]
Zhu G, Peng Y, Wang S. Effect of influent flow rate distribution on the performance of step-feed biological nitrogen removal process[J]. Chemical Engineering Journal, 2007,131:319-328.
[19]
Vaiopoulou E, Aivasidis A. A modified UCT method for biological nutrient removal:configuration and performance[J]. Chemosphere, 2008,72:1062-1068.
Ge S, Peng Y, Wang S, et al. Enhanced nutrient removal in a modified step feed process treating municipal wastewater with different inflow distribution ratios and nutrient ratios[J]. Bioresource technology, 2010,101:9012-9019.
[22]
Tang C, Kuo G, Weiss J. Maximum Nitrogen Removal in the Step-Feed Activated Sludge Process[J]. Water Environment Research, 2007,79:367-374.
Ge S, Zhu Y, Lu C, et al. Full-scale demonstration of step feed concept for improving an anaerobic/anoxic/aerobic nutrient removal process[J]. Bioresource technology, 2012,120:305-313.
[29]
Fu C, Yue X, Shi X, et al. Membrane fouling between a membrane bioreactor and a moving bed membrane bioreactor:Effects of solids retention time[J]. Chemical Engineering Journal, 2017,309:397-408.
[30]
Tian H L, Zhao J Y, Zhang H Y, et al. Bacterial community shift along with the changes in operational conditions in a membrane-aerated biofilm reactor[J]. Applied microbiology and biotechnology, 2015,99:3279-3290.
[31]
Wang Z, Huang F, Mei F, et al. Long-term operation of an MBR in the presence of zinc oxide nanoparticles reveals no significant adverse effects on its performance[J]. Journal of Membrane Science, 2014,471:258-264.
[32]
Ma J, Wang Z, He D. Long-term investigation of a novel electrochemical membrane bioreactor for low-strength municipal wastewater treatment[J]. Water Research, 2015,78:98-110.
[33]
Cao S, Du R, Li B, et al. High-throughput profiling of microbial community structures in an ANAMMOX-UASB reactor treating high-strength wastewater[J]. Applied microbiology and biotechnology, 2016,100:6457-6467.
Katsou E, Alvarino T, Malamis S, et al. Effects of selected pharmaceuticals on nitrogen and phosphorus removal bioprocesses[J]. Chemical Engineering Journal, 2016,295:509-517.
[36]
Zhou Z, Qiao W, Xing C, et al. Microbial community structure of anoxic-oxic-settling-anaerobic sludge reduction process revealed by 454-pyrosequencing[J]. Chemical Engineering Journal, 2015,266:249-257.
[37]
Guo Y, Peng Y, Wang B, et al. Achieving simultaneous nitrogen removal of low C/N wastewater and external sludge reutilization in a sequencing batch reactor[J]. Chemical Engineering Journal, 2016,306:925-932.
[38]
Lei X, Li Y, Wang G, et al. Phaeodactylibacter luteus sp. nov., isolated from the oleaginous microalga Picochlorum sp.[J]. International journal of systematic and evolutionary microbiology, 2015,65:2666-2670.