Comprehensive assessment of primary PM2.5 control technologies for coal-fired power plants |
DENG Shuang1,2, SUN Xian-wei3, SHU Yun1, LI Bo1, GUO Feng-yan1, ZHANG Fan1 |
1. Chinese Research Academy of Environmental Sciences, Beijing 100012, China; 2. State Key Laboratory of Environmental Criteria and Risk Assessment, Beijing 100012, China; 3. Guangzhou Fibre Product Testing and Research Institute, Guangzhou 511400, China |
|
|
Abstract The object of this study is the evaluation of coal-fired power plant flue gas particulate control technologies or their combinations.According to the literature and the expert questionnaire surveys,an assessment model with sixteen evaluation indexes regarding environment,economy and technology was constructed to investigate the primary PM2.5 emission behaviors from coal-fired power plants.Analytic Hierarchy Process (AHP) was used to conducted an assessment for seven coal-fired power plant flue gas particulate control technologies or their combinations.The results showed that the order of priority based on a comprehensive analysis or considering environment is:low-temperature electrostatic precipitation with high-frequency power + wet electrostatic precipitation ≈ electrostatic precipitation with high frequency power + wet electrostatic precipitation > electrostatic-bag precipitation > electrostatic precipitation + wet electrostatic precipitation > bag precipitation > electrostatic precipitation > electrostatic coagulation precipitation.The Electrostatic precipitation could be the best option if considering economics.Otherwise,the bag precipitation was the best if considering technology.
|
Received: 08 August 2017
|
|
|
|
|
[1] |
刘红年,朱焱,林惠娟,等.基于自动站资料的苏州灰霾天气分析[J]. 中国环境科学, 2015,35(3):668-675.
|
[2] |
中华人民共和国环境保护部.2015年环境统计年报[EB/OL]. http://www.zhb.gov.cn/gzfw_13107/hjtj/hjtjnb/201702/P020170223595802837498.pdf.
|
[3] |
EPRI. Economic evaluation of flue gas desulfurization systems[M]. EPRI publications, 1991.
|
[4] |
EPA. Guidance for determining BACT under PSD[EB/OL]. https://www.epa.gov/nsr/guidance-determining-bact-under-psd.
|
[5] |
张洁.火力发电脱硝工程项目方案选择评价研究[D]. 北京:华北电力大学, 2014.
|
[6] |
赵东阳,靳雅娜,张世秋.燃煤电厂污染减排成本有效性分析及超低排放政策讨论[J]. 中国环境科学, 2016,36(9):2841-2848.
|
[7] |
王书肖,郝吉明,陆永琪,等.火电厂烟气脱硫技术的模糊综合评价[J]. 中国电力, 2001,34(12):58-62.
|
[8] |
Zhao X, Hwang B G, Gao Y. A Fuzzy Synthetic Evaluation Approach for Risk Assessment:A Case of Singapore's Green Projects[J]. Journal of Cleaner Production, 2015,115:203-213.
|
[9] |
Rajakarunakaran S, Kumar A M, Prabhu V A. Applications of fuzzy faulty tree analysis and expert elicitation for evaluation of risks in LPG refuelling station[J]. Journal of Loss Prevention in The Process Industries, 2015,33:109-123.
|
[10] |
Fang R. Calculating systems build of manas river basin water environmental carrying capacity[J]. Ground Water, 2014,36(6):105-107.
|
[11] |
Gorai A K, Kanchan, Upadhyay A, et al. Design of fuzzy synthetic evaluation model for air quality assessment[J]. Environment Systems & Decisions, 2014,34(3):456-469.
|
[12] |
Jewell J, Cherp A, Riahi K. Energy security under de-carbonization scenarios:An assessment framework and evaluation under different technology and policy choices[J]. Energy Policy, 2014,65(3):743-760.
|
[13] |
Liu Y, Fang P, Bian D, et al. Fuzzy comprehensive evaluation for the motion performance of autonomous underwater vehicles[J]. Ocean Engineering, 2014,88(5):568-577.
|
[14] |
Lin J F. Using fuzzy synthetic evaluation model to assess technical risk of China's alternative fuel vehicle industry[J]. Advanced Materials Research, 2014,986(4):648-651.
|
[15] |
中国电力企业联合会.中国电力行业年度发展报告[M]. 北京:中国市场出版社, 2016.
|
[16] |
Wang A, Song Q, Tu G, et al. Influence of flue gas cleaning system on characteristics of PM2.5emission from coal-fired power plants[J]. International Journal of Coal Science & Technology, 2014,1(1):4-12.
|
[17] |
Córdoba P, Ochoa-Gonzalez R, Font O, et al. Partitioning of trace inorganic elements in a coal-fired power plant equipped with a wet flue gas desulphurisation system[J]. Fuel, 2012, 92(1):145-157.
|
[18] |
Hua M O, Zhu F H, Wang S, et al. Application of WESP in coal-fired power plants and Its effect on emission reduction of PM2.5[J]. Electric Power, 2013,46(11):62-65.
|
[19] |
Zukeran A, Ikeda Y, Ehara Y, et al. Agglomeration of particles by AC corona-discharge[J]. Electrical Engineering in Japan, 2000, 130(1):30-37.
|
[20] |
Watanabe T, Tochikubo F, Koizurni Y, et al. Submicron particle agglomeration by an electrostatic agglomerator[J]. Journal of Electrostatics, 1995,34(4):367-383.
|
[21] |
Altman R, Offen G, Buckley W, et al. Wet electrostatic precipitation demonstrating promise for fine particulate control-Part Ⅱ[J]. Power Engineering, 2001,105(2):37-39.
|
[22] |
孙现伟,邓双,朱云,等.我国燃煤电厂PM2.5减排潜力预测和分析[J]. 环境科学研究, 2016,29(5):637-645..
|
[23] |
邓双.燃煤电厂PM2.5控制技术评估软件V1.0[CP]. 中国软件著作权:2016SR166821, 2016-05-02.
|
|
|
|