摘要

为利用空调冷凝水的冷量同时解决单层玻璃幕墙夏季高温的问题,将冷凝水用于冷却单层玻璃幕墙,并对其进行了水量、造价及能耗分析.通过Ecotect、CFD模拟、对比了冷凝水冷却玻璃幕墙与普通玻璃幕墙在夏季的光环境和热环境.结果表明:冷凝水冷凝水冷却玻璃幕墙应用规模与建筑冷凝水产量有关,其应用会减少夏季日照辐射,减少幅度在30.1%~41.8%.加装了冷凝水冷却玻璃幕墙的房间温度较普通房间降温幅度为6.64%,白天降温幅度在6.64%~12.73%.综合分析,冷凝水冷却单层幕墙能够较为有效地调节室内环境,同时也是一种新的建筑幕墙改良途径和冷凝水利用方式.

Abstract

Air conditioning condensate water was combined with glass facade in order to utilize the cold of condensate water and decrease the high temperature of glass facade. The condensate water quantity, cost and energy consumption of the condensate water cooling glass facade were analyzed. At the same time, room's light and thermal environment with condensate water cooling glass facade and ordinary glass facade were compared by using Ecotect, CFD simulation in summer. The results showed that the area of condensate water cooling glass facade was related to the condensate water quantity in buildings. The application of condensate water cooling glass facade can reduce the sunshine radiation from 30.1%~41.8%. Its indoor air temperature can reduce 6.64% compared with the ordinary room, the daytime cooling range is 6.64%~12.73%. In summary, condensate water cooling single glass facade can improve the indoor environment effectively and reduce the temperature of the glass facade, and it is a new way of unitization of air conditioning condensate water.

关键词

光环境 / 空调冷凝水 / 冷凝水冷却玻璃幕墙 / 热环境 / 数值模拟

Key words

air conditioning condensate water / condensate water cooling glass façade / light environment / numerical simulation / thermal environment

引用本文

导出引用
郭玉润, 刘俊红, 张文科. 冷凝水冷却玻璃幕墙构建及其对室内环境的影响分析[J]. 中国环境科学. 2020, 40(7): 3143-3149
GUO Yu-run, LIU Jun-hong, ZHANG Wen-ke. Construction and influence analysis on indoor environment of condensate water cooling glass façade[J]. China Environmental Science. 2020, 40(7): 3143-3149
中图分类号: X799.1   

参考文献

[1] 中华人民共和国水利部.2018年中国水资源公报[R]. 北京,水利部水利信息中心, 2018. Ministry of Water Resources of the People's Republic of China. China Water Resources Bulletin 2018[R]. Beijing, Water Resources Information Center, 2018.
[2] 中华人民共和国国家统计局.中国统计年鉴[M]. 北京:中国统计出版社, 2019. National bureau of statistics of the People's Republic of China. China statistical yearbook[M]. Beijing:China Statistics Press, 2019.
[3] Al-Farayedhiaa, Ibrahimin, Gandhidasanp. Condensate as a water source from vapor compression systems in hot and humid regions[J]. Desalination, 2014,349:60-67.
[4] Liu N L, Li Z.The Feasibility on the case that the air conditioning condensate water is used as the make-up water of cooling tower[J]. procedia engineering, 2017,205:3557-3562.
[5] 陈鹏,卢军,张惠民,等.分体空调冷凝水回收利用实验研究[J]. 土木建筑与环境工程, 2012,34(S2):169-172. Chen P, Lu J, Zhang H M, et, al. Experimental study on recovery and utilization of split air conditioning condensate[J] Journal of civil architectural and environmental engineering, 2012,34(S2):169-172.
[6] 王赞社,王芳,刘丰榕,等.湿热地区家用空调冷凝水回收研究[J]. 暖通空调HV&AC,2015,45(12):53-56. Wang Z S, Wang F, Liu F R, et al. Research on condensate recovery of household air conditioning in hot and humid area[J]. Journal of HV&AC, 2015,45(12):53-56.
[7] 丁勇,史丽莎.分体式空调冷凝水回用节能潜力分析[J]. 建筑节能, 2013,39(29):97-101. Ding Y, Shi L S, Liu F R, et al. Analysis on energy saving potential of condensed water reuse in split type air conditioning[J]. Building Energy Efficiency, 2013,39(29):97-101.
[8] 阎冰,曲兴华,张福民.玻璃幕墙眩光污染模拟分析[J]. 城市环境与城市生态, 2014,(1):28-31. Yan B, Qu X H, Zhang F M. Simulation analysis of glare pollution of glass facade[J]. Urban Environment & Urban Ecology, 2014,(1):28-31.
[9] Penić, Milja, Vatin, et al. Double skin facades in energy efficient design[J]. Applied Mechanics and Materials, 2014,680:534-538.
[10] Abed H, Abdelatif M, Nadège T, et al. Combined use of dynamic building simulation and metamodeling to optimize glass facades for thermal comfort[J]. Building and Environment, 2019,(157):47-63.
[11] 洪芳鹏.上海世博会阿尔萨斯案例馆水幕太阳能的设计与施工[J]. 建筑施工, 2012,(9):87-89. Hong F P. Design and construction of water screen and solar energy system in Alsace Case Pavilion in Shanghai World Expo, Building Construction[J]. Building Construction, 2012,(9):87-89.
[12] 张甫仁,刘雪.水介质双层玻璃幕墙节能研究[J]. 墙材革新与建筑节能, 2013,(3):55-57. Zhang F R, Liu X. Study on energy saving of water medium double glass curtain wall.[J] Wall Materials Innovation & Energy Saving in Buildings, 2013,(3):55-57.
[13] 赵方冉,张莎莎,蔡子良.航站楼围护结构水幕墙节能效果分析[J]. 建筑节能, 2014,(5):50-54. Zhao F R, Zhang S S, Cai Z L. Energy analysis of the water curtain wall in terminal envelope.[J]. Building Energy Efficiency, 2014,(5):50-54.
[14] 张忠相,李向阳,马龙.水循环玻璃幕墙热工性能分析与计算[J]. 绿色科技, 2015,(9):317-319. Zhang Z X, Li X Y, Ma L. Analysis and calculation of thermal performance of water circulation glass façade.[J]. Journal of Green Science and Technology, 2015,(9):317-319.
[15] Jiang H, Akira H. A numerical simulation method for analyzing the thermal improvement effect of super-hydrophilic photocatalyst-coated building surfaces with water film on the urban/built environment[J]. Energy & Buildings, 40(6):968-978.
[16] 张雅君,朱娟娟,孙丽华,等.空调冷凝水作为水资源回收利用研究进展[J]. 环境工程, 2017,35(6):142-145,150. Zhang Y, Zhu J J, Sun L H, et al. Research progress of air conditioning condensate water recovery as water source[J]. Environmental Engineering, 2018,(10):76-78.
[17] 民用建筑供暖通风与空气调节设计规范GB 50736-2016[S]. GB 50736-2016, Code for design of heating, ventilation and air conditioning in civil buildings[S].
[18] 金儒霖,张敖春,邹光洁,等.人造水景设计营造与观赏[M]. 中国建筑工业出版社, 2006:115-122. Jin R L, Zhang A C, Zou G J, et al. Artificial waterscape design and viewing[M]. Architecture & Building Press, 2006:115-122.
[19] 王福军.计算流体动力学分析[M]. 北京.清华大学出版社, 2004:120-124. Wang F J. Computational fluid dynamics analysis.[M] Beijing. Tsinghua university press, 2004:120-124.
[20] 韩培,刘志强,李洪飞,等.空调冷凝水收集潜力与价值研究[J]. 给水排水, 2015,(41):141-143. Han P, Liu Z Q, Li H F, et al. Study on condensate collection potential and value of air conditioning[J]. Water&Waster water Engineering, 2015,(41):141-143.
[21] GB50033-2013建筑采光设计标准[S]. GB50033-2013 Architectural lighting design standards[S].

基金

国家自然科学基金资助项目(51708336)